- 30 & 60 minute fire tested to BS-EN 1634-1 & BS476-22
- Tested in full size single & double doorsets, not linear gaps
- No additional mastics or sealants required
- Acoustically tested to full doorset up to 43dB
- Tested in both metal and timber stud partitioning
- Tested with softwood, MDF & hardwood frame sections
- Tested with gaps between 7mm & 30mm
- Tested in a retro-fit scenario to allow use for rectification
- Blue in colour for identification purposes
- Fire rated packers must be used in conjunction with foam
Installation Guide
The doorset installation should be in accordance with BS476-22 / BS-EN 1634-1 and manufacturer’s guidelines.
- During the application, the temperature of the can and room should be between 5°C & 30°C.
- Frame/wall surface must be free from dust and grease.
- Moistening the surfaces before and after the application will ensure faster curing and increase the bonding strength.
- Tested with gaps between 7mm and 30mm.
- Where fixing points occur pack securely using Blue 60 fire rated packers.
- Screw on the applicator gun/nozzle and shake can.
- Hold the can upside down and activate the foam by pressing the valve.
- IMPORTANT – The junction between the door frame and the substrate should be fully filled with Blue 60 fire rated foam.
- Architraves can then be fitted over un-cured foam or alternatively foam can be allowed to cure and then be removed mechanically.